![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 2227966.1 : ODA Patching To 12.1.2.9.0 Failed To Upgrade Local Disk HDD_LOCAL's Firmware
Created from <SR 3-14118828901> Applies to:Oracle Database Appliance X5-2 - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. This issue is primarily seen during upgrade to ODA 12.1.2.9.0 SymptomsFail to upgrade local disk HDD_LOCAL's firmware during ODA patching 12.1.2.9.0. INFO: 2017-01-28 15:55:59: Unable to update the Disk c0d0 to : H109060SESUN600G A72A
INFO: 2017-01-28 15:55:59: Unable to update the Disk c0d1 to : H109060SESUN600G A72A INFO: 2017-01-28 15:56:07: Patch not found for the Controller : c0 WARNING: 2017-01-28 15:56:07: Unable to update the following devices : INFO: 2017-01-28 15:56:07: Disk-c0d0 INFO: 2017-01-28 15:56:07: Disk-c0d1
The local disk upgrade is at dom0 and the dom0 log showing: 2017-01-28 17:39:19,123 STORAGE DEBUG Running: /usr/sbin/fwupdate update disk-firmware -n c0d0 -f /opt/oracle/oak/pkgrepos/thirdpartypkgs/Firmware/Disk/HITACHI/H109060SESUN600G/A72A/Base/H109060SE.A72A.fw --silent-no-reboot -q -o /opt/oracle/oak/log/drn1d0/patch/12.1.2.9.0/c0d06572.log 2017-01-28 17:39:30,890 STORAGE DEBUG Running: /usr/sbin/fwupdate update disk-firmware -n c0d1 -f /opt/oracle/oak/pkgrepos/thirdpartypkgs/Firmware/Disk/HITACHI/H109060SESUN600G/A72A/Base/H109060SE.A72A.fw --silent-no-reboot -q -o /opt/oracle/oak/log/drn1d0/patch/12.1.2.9.0/c0d16572.log
Changesupgrade to 12.1.2.9 CauseThe local disk firmware upgrade failure caused by a known issue and is tracked by BUG 24901967. SolutionThe bug is fixed in version 12.1.2.10, upgrade to 12.1.2.10 can fix this issue. OR Ignore this issue as the patching process can be continued and can run ODA 12.1.2.9.0 with the lower HDD_LOCAL firmware, it does not harm anything. Following snippet shows an upgraded ODA at version 12.1.2.9.0 with lower HDD_LOCAL firmware
INFO: 2017-01-03 12:41:27: Reading the metadata file now...
Component Name Installed Version Proposed Patch Version --------------- ------------------ ----------------- Controller_INT 4.230.40-3739 Up-to-date Controller_EXT 09.00.00.00 Up-to-date Expander 0018 Up-to-date SSD_SHARED { [ c1d20,c1d21,c1d22, A29A Up-to-date c1d23,c1d44,c1d45,c1 d46,c1d47 ] [ c1d16,c1d17,c1d18, A29A Up-to-date c1d19,c1d40,c1d41,c1 d42,c1d43 ] } HDD_LOCAL A720 A72A <<<<<<<<<<<!!!!!!!!!! HDD_SHARED A3A0 Up-to-date ILOM 3.2.7.26.a r112579 Up-to-date BIOS 30090200 Up-to-date IPMI 1.8.12.4 Up-to-date HMP 2.3.5.2.5 Up-to-date OAK 12.1.2.9.0 Up-to-date OL 6.8 Up-to-date OVM 3.2.11 Up-to-date GI_HOME 12.1.0.2.161018(2400 Up-to-date 6101,23854735) DB_HOME 12.1.0.2.161018(2400 Up-to-date 6101,23854735) ASR 5.5.1 Up-to-date If customer insists on upgrading the firmware, then it can be done manually using the following steps (at high level, refer SR 3-13907521791 for the steps): - Copy firmware file from /opt/oracle/oak/pkgrepos/thirdpartypkgs/Firmware/Disk/HITACHI/H109060SESUN600G/A72A/Base to dom0 (both nodes)
Goal
While patching/upgrading ODA to 12.1.2.9.0, the local disk HDD_LOCAL's firmware does not get updated. Attachments This solution has no attachment |
||||||||||||
|