Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2227966.1
Update Date:2017-03-30
Keywords:

Solution Type  Problem Resolution Sure

Solution  2227966.1 :   ODA Patching To 12.1.2.9.0 Failed To Upgrade Local Disk HDD_LOCAL's Firmware  


Related Items
  • Oracle Database Appliance X5-2
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Database Appliance>DB: ODA_EST
  •  




Created from <SR 3-14118828901>

Applies to:

Oracle Database Appliance X5-2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
This issue is primarily seen during upgrade to ODA 12.1.2.9.0

Symptoms

 Fail to upgrade local disk HDD_LOCAL's firmware during ODA patching 12.1.2.9.0.

INFO: 2017-01-28 15:55:59: Unable to update the Disk c0d0 to : H109060SESUN600G A72A
INFO: 2017-01-28 15:55:59: Unable to update the Disk c0d1 to : H109060SESUN600G A72A
INFO: 2017-01-28 15:56:07: Patch not found for the Controller : c0
WARNING: 2017-01-28 15:56:07: Unable to update the following devices :
INFO: 2017-01-28 15:56:07: Disk-c0d0
INFO: 2017-01-28 15:56:07: Disk-c0d1

  

 The local disk upgrade is at dom0 and the dom0 log showing:

2017-01-28 17:39:19,123 STORAGE DEBUG Running: /usr/sbin/fwupdate update disk-firmware -n c0d0 -f /opt/oracle/oak/pkgrepos/thirdpartypkgs/Firmware/Disk/HITACHI/H109060SESUN600G/A72A/Base/H109060SE.A72A.fw --silent-no-reboot -q -o /opt/oracle/oak/log/drn1d0/patch/12.1.2.9.0/c0d06572.log
2017-01-28 17:39:25,867 STORAGE DEBUG Failed to run the cmd: /usr/sbin/fwupdate update disk-firmware -n c0d0 -f /opt/oracle/oak/pkgrepos/thirdpartypkgs/Firmware/Disk/HITACHI/H109060SESUN600G/A72A/Base/H109060SE.A72A.fw --silent-no-reboot -q -o /opt/oracle/oak/log/drn1d0/patch/12.1.2.9.0/c0d06572.log
2017-01-28 17:39:25,867 STORAGE ERROR ERROR: Invalid device target type

2017-01-28 17:39:30,890 STORAGE DEBUG Running: /usr/sbin/fwupdate update disk-firmware -n c0d1 -f /opt/oracle/oak/pkgrepos/thirdpartypkgs/Firmware/Disk/HITACHI/H109060SESUN600G/A72A/Base/H109060SE.A72A.fw --silent-no-reboot -q -o /opt/oracle/oak/log/drn1d0/patch/12.1.2.9.0/c0d16572.log
2017-01-28 17:39:36,744 STORAGE DEBUG Failed to run the cmd: /usr/sbin/fwupdate update disk-firmware -n c0d1 -f /opt/oracle/oak/pkgrepos/thirdpartypkgs/Firmware/Disk/HITACHI/H109060SESUN600G/A72A/Base/H109060SE.A72A.fw --silent-no-reboot -q -o /opt/oracle/oak/log/drn1d0/patch/12.1.2.9.0/c0d16572.log
2017-01-28 17:39:36,745 STORAGE ERROR ERROR: Invalid device target type

  

Changes

 upgrade to 12.1.2.9

Cause

 The local disk firmware upgrade failure caused by a known issue and is tracked by BUG 24901967.

Solution

The bug is fixed in version 12.1.2.10, upgrade to 12.1.2.10 can fix this issue.

OR

Ignore this issue as the patching process can be continued and can run ODA 12.1.2.9.0 with the lower HDD_LOCAL firmware, it does not harm anything. Following snippet shows an upgraded ODA at version 12.1.2.9.0 with lower HDD_LOCAL firmware

 

INFO: 2017-01-03 12:41:27: Reading the metadata file now...
Component Name Installed Version Proposed Patch Version
--------------- ------------------ -----------------
Controller_INT 4.230.40-3739 Up-to-date
Controller_EXT 09.00.00.00 Up-to-date
Expander 0018 Up-to-date
SSD_SHARED {
[ c1d20,c1d21,c1d22, A29A Up-to-date
c1d23,c1d44,c1d45,c1
d46,c1d47 ]
[ c1d16,c1d17,c1d18, A29A Up-to-date
c1d19,c1d40,c1d41,c1
d42,c1d43 ]
}
HDD_LOCAL A720 A72A <<<<<<<<<<<!!!!!!!!!!
HDD_SHARED A3A0 Up-to-date
ILOM 3.2.7.26.a r112579 Up-to-date
BIOS 30090200 Up-to-date
IPMI 1.8.12.4 Up-to-date
HMP 2.3.5.2.5 Up-to-date
OAK 12.1.2.9.0 Up-to-date
OL 6.8 Up-to-date
OVM 3.2.11 Up-to-date
GI_HOME 12.1.0.2.161018(2400 Up-to-date
6101,23854735)
DB_HOME 12.1.0.2.161018(2400 Up-to-date
6101,23854735)
ASR 5.5.1 Up-to-date

  

 If customer insists on upgrading the firmware, then it can be done manually using the following steps (at high level, refer SR 3-13907521791 for the steps):

- Copy firmware file from /opt/oracle/oak/pkgrepos/thirdpartypkgs/Firmware/Disk/HITACHI/H109060SESUN600G/A72A/Base to dom0 (both nodes)
- Shutdown repositories
- update the firmware as
fwupdate update disk-firmware -f H109060SE.A72A.fw -n c0d0
fwupdate update disk-firmware -f H109060SE.A72A.fw -n c0d1
- reboot the node

 

 

Goal

 

While patching/upgrading ODA to 12.1.2.9.0, the local disk HDD_LOCAL's firmware does not get updated.