Asset ID: |
1-72-2227579.1 |
Update Date: | 2017-02-01 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2227579.1
:
Cannot Reconfigure ServerB Network Interfaces, During Epap Upgrade
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
|
In this Document
Created from <SR 3-14115805091>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EPAP 14.0 and later
Information in this document applies to any platform.
Symptoms
Engineer cannot configure interface after IPM and application install
Cause
The engineer changed the time on the server. This made current version of the config file younger than the preceding versions
Solution
Checked the file out.
Deleted the file from repository
Checked the file in
Attachments