Solution Type
Problem Resolution Sure
Solution
2227553.1
:
EPAP 16.1 Upgrade Issue : Application Software Failing to Start
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
|
In this Document
Created from <SR 3-14118452001>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EPAP 16.0 and later
Information in this document applies to any platform.
Symptoms
Application software failing to start after upgrade
Cause
The logs show that the elapdev does not have access to EuiDB. Further investigation showed that the EuiDB database was not present.
The application will not run without the EuiDB and access to it.
Solution
Issue resolved by :
- Copy EuiDB directory from mate
- Copy mysql user table from mate
- Grant privileges for EuiDB
- Flush privileges
- Manually reset ReplicationStart software
Attachments