Solution Type Problem Resolution Sure Solution 2227167.1 : System hits error: ERROR: Unexpected non-zero POK value, adjusting state machine
Created from <SR 3-13648312091> Applies to:Netra SPARC T4-1 Server - Version All Versions and laterInformation in this document applies to any platform. SymptomsAfter motherboard replacement, the system hits error: CauseThis error can result from motherboard FPGA problems. This error message indicates a benign incident on powerup if only occurs once during the powerup. SolutionIn this case, the resolution was to replace the faulty replacement motherboard. References<NOTE:1558027.1> - T3-1 & T4-1 Power Requirements & The Possible Misdiagnosis of Input Power Interruptions<NOTE:1443866.1> - POK power glitches & regulator faults cause T3-x/T4-x/NetraT3-1/NetraT4-x/T3-1B/T4-1B/NetraT3-1B/Netra T4-1B to power down unexpectedly <BUG:25130603> - ERROR: UNEXPECTED NON-ZERO POK VALUE, ADJUSTING STATE MACHINE <NOTE:1951488.1> - T4-1/T4-2, System shut down due to ERROR: Unexpected zero POK value, adjusting state machine Attachments This solution has no attachment |
||||||||||||
|