Asset ID: |
1-72-2226847.1 |
Update Date: | 2017-01-31 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2226847.1
:
ELAP: Init 6 Hung : HA Status Hung Confused
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS ELAP LSMS
|
In this Document
Created from <SR 3-14112959761>
Applies to:
Oracle Communications EAGLE (Software) - Version ELAP 9.0 and later
Information in this document applies to any platform.
Symptoms
HA status on both ELAP servers going to Standby
Cause
User attempting a failover
Bug in drbd
Solution
1)Init 3 on EPAP B
2) Power Host Reboot on EPAP A from OOBM
3) Init 4 on EPAP B
Attachments