![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2226827.1 : Oracle Key Manager (OKM) - Potential Timeouts During Join Cluster Of New T7-1 KMA's To Existing X2100/X2200 M2 KMA Cluster
In this Document
Applies to:Oracle Key Manager - Version 3.0 and laterInformation in this document applies to any platform. SymptomsThere have been some instances where timeouts are observed when a new NS T7-1 KMA is joining a cluster with x2100/x2200 m2 KMA’s, because the x2100/x2200 m2 platforms are too slow and the T7-1 KMA's sometimes times out as if the x2100/x2200 KMA's are not responding. Causex2100/x2200 m2 KMA performance SolutionThe recommendation is to utilize the Initial Replication Acceleration feature during the join cluster operation. From the OKM 3 Administration Guide located here: http://docs.oracle.com/cd/E50985_03/index.html Reference the "Joining an Existing Cluster" section starting on page 49. Specifically in Step 9, make sure to answer yes "Y" for the following question: ** It might take some time for this KMA to be updated with information from other
**
Attachments This solution has no attachment |
||||||||||||||||
|