![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2225169.1 : SL8500 - Partitioned SL8500 is unable to ENTER cart via CAP from 2nd partition
In this Document
Created from <SR 3-13851527828> Applies to:Sun StorageTek SL8500 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]IBM z/OS on System z SymptomsPartitioned SL8500 is unable to ENTER cart via CAP from 2nd partition.
ChangesCode update from FRS_4.73 to FRS_8.51 CausePartition1 Rail1/2 = Open System (ACSLS) Partition2 Rail3/4 = Mainframe (HSC) LSM0 and LSM1 are online to Open System hosts and are offline to Mainframe hosts. When cart is entered from partition2 mainframe hosts, library responds 'LSM not ready' and enter operation would fail. Status for LSM1 is ... OFFLINE - READY - MANUAL - UNALLOCATED
SolutionVary online LSM1 to all hosts. LSM1 needs to be online for CAP access. KB Doc "How to Modify/Vary a CAP Offline/Online In HSC (Doc ID 1546756.1)" indicates ; Note: SL8500 partitioned Fixed problem after varying LSM1 online to partition2 mainframe hosts with LSM1 status as below. ONLINE - READY - AUTOMATIC - UNALLOCATED Attachments This solution has no attachment |
||||||||||||||||||
|