Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2224843.1
Update Date:2017-08-09
Keywords:

Solution Type  Problem Resolution Sure

Solution  2224843.1 :   T10000 - The Drive Was Requested To Write To Tape But The Hardware Generated An Error, FSC 396E  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
  • Sun StorageTek T10000A Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Remote
  •  




In this Document
Symptoms
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN)
Reason: Confidentual for service personnel
Created from <SR 3-13949234696>

Applies to:

Sun StorageTek T10000A Tape Drive - Version All Versions and later
Sun StorageTek T10000B Tape Drive
Information in this document applies to any platform.

Symptoms

*** Alarm Description ***
FSC(396E): The drive was requested to write to tape but the hardware generated an error.
The drive was requested to write to tape but the hardware generated an error.

WRT_STREAMING_SIGNATURE_RBC_PERM

Drive Details
2017-01-01 16:47:16

DMOD                 Dismounts   Unique Tapes     Total Perms        Tapes w/ Perms    TotalTemps      Tapes w/ Temps
531004007747     49               49                     >>43<<             41                        573                 48

Totals 49 43

1,4,-1,1,4 3 531004007747 531000205382 T10000a StorageTek empty 1.52.106-5.30 10.30.13.207

2016-12-28T05:40:30.026 warn 1.4.-1.1.4 3992 "Warning from device", Data=!|CDATA|drive 1,4,-1,1,4: rewindUnload Successful with unitCheck 396E (cartLabel = H01378T1)||
2016-12-28T08:02:01.049 warn 1.4.-1.1.4 3992 "Warning from device", Data=!|CDATA|drive 1,4,-1,1,4: rewindUnload Successful with unitCheck 396E (cartLabel = I01743T1)||
2016-12-28T10:45:35.378 warn 1.4.-1.1.4 3992 "Warning from device", Data=!|CDATA|drive 1,4,-1,1,4: rewindUnload Successful with unitCheck 396E (cartLabel = I02000T1)||
2016-12-28T13:26:37.344 warn 1.4.-1.1.4 3992 "Warning from device", Data=!|CDATA|drive 1,4,-1,1,4: rewindUnload Successful with unitCheck 396E (cartLabel = I02303T1)||
2016-12-28T17:16:52.839 warn 1.4.-1.1.4 3992 "Warning from device", Data=!|CDATA|drive 1,4,-1,1,4: rewindUnload Successful with unitCheck 396E (cartLabel = I01771T1)||
2016-12-28T19:15:06.441 warn 1.4.-1.1.4 3992 "Warning from device", Data=!|CDATA|drive 1,4,-1,1,4: rewindUnload Successful with unitCheck 396E (cartLabel = H00127T1)||
2016-12-28T21:14:33.226 warn 1.4.-1.1.4 3992 "Warning from device", Data=!|CDATA|drive 1,4,-1,1,4: rewindUnload Successful with unitCheck 396E (cartLabel = I01274T1)||
2017-01-01T14:43:33.380 warn 1.4.-1.1.4 3992 "Warning from device", Data=!|CDATA|drive 1,4,-1,1,4: rewindUnload Successful with unitCheck 396E (cartLabel = H01276T1)|
2017-01-01T16:48:05.217 warn 1.4.-1.1.4 3992 "Warning from device", Data=!|CDATA|drive 1,4,-1,1,4: rewindUnload Successful with unitCheck 396E (cartLabel = I00312T1)||

Cause

FSC: 396E RO_FSC_WRT_STREAMING_SIGNATURE_RBC_PERM
MIM Code: INOPERABLE
FRU: HARDWARE CONF: 90%
FRU: MICROCODE CONF: 10%
Summary: |WRITE IN INVALID| *** | *** |

Field Text:
The write hardware was not generating enough signature info so the write was stopped.
 

Solution

Replaced tape drive T10000A.

References

<BUG:15556427> - SUNBT6830689 T10KA FC - ATTACHED TO FUJITSU CENTRICSTOR - R/W ERRORS