Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2224405.1
Update Date:2017-01-23
Keywords:

Solution Type  Problem Resolution Sure

Solution  2224405.1 :   Table Dimensions Do Not Match Error During Target Release Download to Target Rel 46.3.0.0.2  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-14056421951>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EAGLE 46.0 and later
Information in this document applies to any platform.

Symptoms

The "act-upgrade:action=getrel" command is failing

Cause

This is a known bug when upgrading from R46.0 to R46.3 : BUG 20349858
 
We are facing problem for the R46.0.0 to R46.3 upgrade path.
The GETREL for target R46.3 is failing in R46.0.0.
Problem is due to the fact that there is a BLMCAP file size change between R46.0.0 and R46.3 releases and fix for Bug 20424744 is not available in R46.0.0.
Same BLMCAP file size difference is there between R46.0.1/R46.0.3 and R46.3 releases Or R46.2 and R46.3 releases.
However the fix for Bug 20424744 (available in R46.0.1 and later) / BUG 20349858 (in R46.2) will take care of the BLMCAP file size change.
 

Solution

It is not possible to directly upgrade from R46.0 to R46.3.
It must be first upgraded to R46.0.3 or R46.2 and then to 46.3.
 

References

<BUG:20424744> - R46.2_ENUM:GETREL FAILS WHILE UPGRADING FROM 45.0.1-64.70.35-46.2.0-65.40.0
<BUG:20349858> - R46.2_ENUM:GETREL FAILS WHILE UPGRADING FROM 45.0.1-64.70.35-46.2.0-65.40.0

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback