Created from <SR 3-14034911951> Applies to:Oracle Communications EAGLE (Hardware) - Version EPAP 12.x and laterInformation in this document applies to any platform. SymptomsEPAP is having an issue with MySql replication on both EPAPs with this message : manageBannerInfo -l
ID: MYSQL_REPLIC_FAIL MSG: Attempt to restart MySQL replication failed
CauseLikely a sync issue between both EPAP. We could see the failure on both EPAPs. MySqL is the format of the database for the PDB. SolutionFrom EPAP B, run these commands : cd /usr/TKLC/epap/config