Solution Type  Problem Resolution Sure

Solution  2223582.1 :   MYSQL_REPLIC_FAIL on EPAP Platform  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-14034911951>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EPAP 12.x and later
Information in this document applies to any platform.

Symptoms

EPAP is having an issue with MySql replication on both EPAPs with this message :

manageBannerInfo -l
ID: MYSQL_REPLIC_FAIL
MSG: Attempt to restart MySQL replication failed

 

Cause

Likely a sync issue between both EPAP.  We could see the failure on both EPAPs.

MySqL is the format of the database for the PDB.
 

Solution

From EPAP B, run these commands :

cd /usr/TKLC/epap/config
./resetReplication

it solved the issue on both EPAPs
 