Asset ID: |
1-72-2223069.1 |
Update Date: | 2017-03-17 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2223069.1
:
One Association Containing a Discard Reason as "M3UA PDU Error"
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-13955660381>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EAGLE 3x.x and later
Information in this document applies to any platform.
Symptoms
One Association, containing discard reason as "M3UA PDU Error"
> pass:loc=1307:cmd="msucount -a hlrm02a"
eaglestp 17-01-02 20:21:42 EAGLE5 44.0.5-64.34.26
MSUCOUNT: MSU Count Report
--------------------------
IP Connection Measurements
--------------------------
Receive Counts Transmit Counts
---------------------------------- ---------------------------
msus bytes msus bytes
---------- ------------------ ---------- ----------
23 3452 447 60076
Receive Discard Counts Transmit Discard Counts
---------------------------------- ---------------------------------
reason count reason count
---------------------- ----------- ---------------------- ----------
M3UA PDU error 195 no transmit discard counts
Cause
There is a protocol field which is wrong in the received packet.
Because this is the meaning of the error message plus the fact that Eagle is discarding the message.
Solution
To configure the Network Appearance properly.
Modifying "Network Appearance" parameter's value as "0" for ITU-N Point codes solved the issue : ent-na:type=itun:na=0
Attachments