Asset ID: |
1-72-2222552.1 |
Update Date: | 2018-03-02 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2222552.1
:
SL8500 - Console Warning : HBYAB ETH2 Link is Down
Related Items |
- Sun StorageTek SL8500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-13938415831>
Applies to:
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
HBYAB ETH2 link is down.
Cause
warning in regards to the HBT A card.
2016-12-29T01:46:11.975, 1.0.0.0.0, root, default, BondMonitor, 0, warn, 6004, "Link state DOWN - Board : hbta, iface : eth2 (HBYAB)"
Solution
1. Switch library control to HBC B.
2. Reboot library control HBC A.
3. Switch back to library control to HBC A.
4. Monitor the library health for a period and collect a new library snapshot.
5. If the HBT A card fails or is still showing errors, switch to HBC B and replace the HBT A card.
References
<NOTE:1968691.1> - SL8500 - Network Interface On The Library Failed - "Link state DOWN - Board : HBZA
Attachments
This solution has no attachment