Solution Type Problem Resolution Sure Solution 2221281.1 : IMF of the System Does Not Display Information in ProDiag Application
In ProDiag one IMF of the system does not show any information In this Document
Created from <SR 3-13576148031> Applies to:Oracle Communications Performance Intelligence Center (PIC) Software - Version 9.0.4 to 10.1.5 [Release 9.0 to 10.0]Information in this document applies to any platform. SymptomsThere are no information from one IMF of the system monitored by PIC on views of ProDiag. Changes
CauseThe process "inetmerge", that allows to exchange information with ProDiag shows no connection for both servers IMF-1A and IMF-1B from the WL1 box. The command "inetmstat" displays the state of inetmerge shows the following result for both IMF servers: nodeId InetMerge State dir dSeq dTime updTime info
IMF-1A DownConnecting From 0 0.00 07:25:28 IMF-1B DownConnecting From 0 0.00 07:25:28 By checking on both IMF servers, the process "inetmerge" does not run. SolutionConnect on both IMF servers and as cfguser, start the process inetmerge with the command: pm.set on inetmerge
Then, check the status from WL1, as cfguser: inetmstat
Expected output: IMF-1A Active From 0 0.00 04:19:38
IMF-1B Active From 0 0.00 04:19:38 Then, verify whether there are data displayed on ProDiag for these equipment.