![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2220477.1 : SL150 - Power Supply Degraded, Fault Code 9013 found! PS_FAN_SPEED_WARNING
In this Document
Created from <SR 3-13956790191> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. SymptomsFault Code 9013 found! PS_FAN_SPEED_WARNING 016-12-18T21:23:33.463 9013 PS FAN SPEED WARNING CausePossible defective power supply. SolutionThe fan should be checked for obstruction or for some temperature issue first before replacing. If all looks good, replace the Power Supply. SL150 - How to Remove/Replace a Power Supply CRU on the StorageTek SL150 Modular Tape Library [VCAP] (Doc ID 1473762.1) Applies to:StorageTek SL150 Modular Tape Library Attachments This solution has no attachment |
||||||||||||||||||||
|