Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2220477.1
Update Date:2017-11-13
Keywords:

Solution Type  Problem Resolution Sure

Solution  2220477.1 :   SL150 - Power Supply Degraded, Fault Code 9013 found! PS_FAN_SPEED_WARNING  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Cause
Solution
 Applies to:
References


Created from <SR 3-13956790191>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Fault Code 9013 found! PS_FAN_SPEED_WARNING

016-12-18T21:23:33.463 9013 PS FAN SPEED WARNING
Module 1 Top PowerSupply
Check power supply fan for obstruction. Replace Power Supply

Cause

 Possible defective power supply.

Solution

The fan should be checked for obstruction or for some temperature issue first before replacing.

If all looks good, replace the Power Supply.

SL150 - How to Remove/Replace a Power Supply CRU on the StorageTek SL150 Modular Tape Library [VCAP] (Doc ID 1473762.1)

Applies to:

StorageTek SL150 Modular Tape Library


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback