Solution Type  Problem Resolution Sure

Solution  2219675.1 :   VSM5 - Cannot VARY RTD Online; ECAM Error CC=5, RC=109 After Changing Two Switch Port Addresses  


Related Items
  • Sun StorageTek Virtual Tape Control Software (VTCS)
  •  
  • Sun StorageTek VSM5 System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-13907586301>

Applies to:

Sun StorageTek VSM5 System - Version All Versions and later
Sun StorageTek Virtual Tape Control Software (VTCS) - Version 6.0 and later
Information in this document applies to any platform.

Symptoms

Two RTDs are unable to vary online to the VTSS and VTCS.

SLS6684I RTD rtdname ON VTSS vtssname RETURNED ECAM ERROR CC=5 RC=109 

Changes

The IODEF and physical ports on the switch were changed for the RTDs in question.

Cause

When the switch port addresses are changed for RTDs, this requires a Field Engineer (FE) to go onsite and reconfigure the VCF card.  The VCF card is configured for specific port addresses.

Solution

Open a Service Request in My Oracle Support using the serial number of the VTSS, to which the RTDs are attached, and ask for support to review and verify whether this is the cause of the problem.

Also, review Doc ID 1449264.1 for FICON RTD and CLINK Configuration Information.