![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2219675.1 : VSM5 - Cannot VARY RTD Online; ECAM Error CC=5, RC=109 After Changing Two Switch Port Addresses
In this Document
Created from <SR 3-13907586301> Applies to:Sun StorageTek VSM5 System - Version All Versions and laterSun StorageTek Virtual Tape Control Software (VTCS) - Version 6.0 and later Information in this document applies to any platform. SymptomsTwo RTDs are unable to vary online to the VTSS and VTCS. SLS6684I RTD rtdname ON VTSS vtssname RETURNED ECAM ERROR CC=5 RC=109 ChangesThe IODEF and physical ports on the switch were changed for the RTDs in question. CauseWhen the switch port addresses are changed for RTDs, this requires a Field Engineer (FE) to go onsite and reconfigure the VCF card. The VCF card is configured for specific port addresses. SolutionOpen a Service Request in My Oracle Support using the serial number of the VTSS, to which the RTDs are attached, and ask for support to review and verify whether this is the cause of the problem. Also, review Doc ID 1449264.1 for FICON RTD and CLINK Configuration Information. Attachments This solution has no attachment |
||||||||||||||||||||
|