Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2219191.1
Update Date:2018-01-11
Keywords:

Solution Type  Problem Resolution Sure

Solution  2219191.1 :   T10000A - FSC 5905, Machine Reel Amplifier Was Saturated For Too Long  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Remote
  •  




In this Document
Symptoms
Cause
Solution
 Applies to:


Created from <SR 3-13927030455>

Applies to:

Sun StorageTek T10000A Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Hostname: not_applicable
Product Type: T10000A
Summary:Machine reel amplifier was saturated for too long.

Fault event description:Machine reel amplifier was saturated for too long.
receiver_id: SDP2-2.3.2
siteID: 1412270340620.0
Machine reel amplifier was saturated for too long.

Symptoms

FSCs:
5530:The velocity difference between the two reels exceeded limits defined by the software indicating poor tape tension control.
FSC(5905): Machine reel amplifier was saturated for too long.

Cause

 Metal ring from the bottom of a tape cartridge stuck to file reel motor

Solution

Removed the  the metal ring from the tape drive.

Applies to:

Sun StorageTek T10000A Tape Drive


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback