Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2216544.1
Update Date:2017-03-27
Keywords:

Solution Type  Problem Resolution Sure

Solution  2216544.1 :   UAM 0571 Sentinel Socket Is Inactive  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-13538666941>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 46.0 and later
Information in this document applies to any platform.

Symptoms

1st Case : Alarm "Sentinel socket is inactive" is observed on several STC cards : 

3882.0571 * SLK 2105,A5 stp1 Sentinel socket is inactive
3883.0571 * SLK 2105,A6 stp1 Sentinel socket is inactive
3884.0571 * SLK 2105,A7 stp2 Sentinel socket is inactive
3886.0571 * SLK 2105,A8 stp2 Sentinel socket is inactive
3887.0571 * SLK 2106,A2 stp1 Sentinel socket is inactive
3889.0571 * SLK 2106,A3 stp1 Sentinel socket is inactive
3890.0571 * SLK 2106,A4 stp2 Sentinel socket is inactive
3891.0571 * SLK 2106,A5 stp 2 Sentinel socket is inactive

 

2nd Case : Alarm "Sentinel socket is inactive" is observed on one card

 

Cause

1rst case : this ha been triggered by the IMF server becoming down

2nd case :  as the IP port B was not getting pinged from the IMF & there were few output queue drops,  so looks like the port was hung.

Solution

1rst case :

- Since the IMF server is down then there will get the Sentinel socket Alarm on EAGLE/STP. Hence suggested customer to make the IMF server UP and Running to recover the Sentinel socket Alarm.
- 2 cards remained with the EIS status inactive (rept-stat-card:loc=xxx:mode=full). They finally recovered after a long time.

SIGNALING LINK STATUS
SLK  PST      LS   CLLI     E5IS
A    IS-NR    ls1  eagle    INACTIVE
B    IS-NR    ls1  eagle    INACTIVE

 

2nd case : Either

- move the cable plug-out, plug-in

- or reset the port on switch side

- or reset the card

 


Attachments