Solution Type Problem Resolution Sure Solution 2216544.1 : UAM 0571 Sentinel Socket Is Inactive
In this Document
Created from <SR 3-13538666941> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 46.0 and laterInformation in this document applies to any platform. Symptoms1st Case : Alarm "Sentinel socket is inactive" is observed on several STC cards : 3882.0571 * SLK 2105,A5 stp1 Sentinel socket is inactive
3883.0571 * SLK 2105,A6 stp1 Sentinel socket is inactive 3884.0571 * SLK 2105,A7 stp2 Sentinel socket is inactive 3886.0571 * SLK 2105,A8 stp2 Sentinel socket is inactive 3887.0571 * SLK 2106,A2 stp1 Sentinel socket is inactive 3889.0571 * SLK 2106,A3 stp1 Sentinel socket is inactive 3890.0571 * SLK 2106,A4 stp2 Sentinel socket is inactive 3891.0571 * SLK 2106,A5 stp 2 Sentinel socket is inactive
2nd Case : Alarm "Sentinel socket is inactive" is observed on one card
Cause1rst case : this ha been triggered by the IMF server becoming down 2nd case : as the IP port B was not getting pinged from the IMF & there were few output queue drops, so looks like the port was hung. Solution1rst case : - Since the IMF server is down then there will get the Sentinel socket Alarm on EAGLE/STP. Hence suggested customer to make the IMF server UP and Running to recover the Sentinel socket Alarm. SIGNALING LINK STATUS
SLK PST LS CLLI E5IS A IS-NR ls1 eagle INACTIVE B IS-NR ls1 eagle INACTIVE
2nd case : Either - move the cable plug-out, plug-in - or reset the port on switch side - or reset the card