Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2215458.1
Update Date:2018-03-02
Keywords:

Solution Type  Problem Resolution Sure

Solution  2215458.1 :   T10000b - The ASC Detected A Work Item On The Queue, FSC 2601  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  
  • Tools>Primary Use>Performance
  •  


The ASC detected a work item on the queue

In this Document
Symptoms
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Microcode issue
Created from <SR 3-13872172942>

Applies to:

Sun StorageTek T10000B Tape Drive - Version All Versions to Not Applicable [Release All Releases to N/A]
Information in this document applies to any platform.

Symptoms

The ASC detected a work item on the queue.

FSC: 2601 |INVALID UCODE |DATA RECEIVED

Cause

FSC Dictionary Description:
MODEL = T10000B
FSC = 2601
(FSC Match Found in Rev. 1.52)

FSC: 2601 ASC_FSC_WORK_ITEM_ON_QUEUE

MIM Code: INOPERABLE

FRU: MICROCODE CONF: 100%

Summary: |INVALID UCODE |DATA RECEIVED | *** |

Field Text:
The ASC detected a work item on the queue.

Engineering Text:
The ASC detected a work item on the queue. SNO NOTE: ASC_FSC_UNEXPECTED_MSG is indicated as the ASC only expects wait items at the top of the queue when processing a message in asc_main_loop and this resulted in a call to asc_sno because the state of the ASC is in question.

Solution

 Oracle recommends that you need to upgrade the Drive firmware to latest level Latest GA Version: 1.52.206 or higher.

References

<NOTE:2088800.1> - T10000 - No Perm Found In Log Bundle

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback