![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2213101.1 : One SLK Is Down After Eagle Upgrade
In this Document
Created from <SR 3-13816343821> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and laterInformation in this document applies to any platform. SymptomsOne link is OOS, after to the upgrade to R46.3 CauseThe links had been manually deactivated SLK PST LS CLLI E5IS
A OOS-MT-DSBLD lsgwto2 ----------- INACTIVE
SolutionThe SLK has to be allowed : > act-slk:loc=3207:port=a
> rept-stat-card:loc=3207:mode=full
eaglestp 16-12-09 06:44:57 EST EAGLE 46.3.0.0.2-68.28.0 CARD VERSION TYPE GPL PST SST AST 3207 138-028-000 DCM IPGHC IS-NR Active ----- ALARM STATUS = No Alarms. ... SIGNALING LINK STATUS SLK PST LS CLLI E5IS A IS-NR lsgwto2 ----------- INACTIVE
Attachments This solution has no attachment |
||||||||||||||||
|