Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2213101.1
Update Date:2016-12-14
Keywords:

Solution Type  Problem Resolution Sure

Solution  2213101.1 :   One SLK Is Down After Eagle Upgrade  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-13816343821>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Information in this document applies to any platform.

Symptoms

One link is OOS, after to the upgrade to R46.3

Cause

The links had been manually deactivated
 
It is indicated in the rept-stat-card : DSBD=Disabled

  SLK  PST            LS      CLLI        E5IS
  A    OOS-MT-DSBLD  lsgwto2 ----------- INACTIVE

 

Solution

The SLK has to be allowed  :
> act-slk:loc=3207:port=a
> rept-stat-card:loc=3207:mode=full

  eaglestp 16-12-09 06:44:57 EST EAGLE 46.3.0.0.2-68.28.0
  CARD VERSION TYPE GPL PST SST AST
  3207 138-028-000 DCM IPGHC IS-NR Active -----
  ALARM STATUS = No Alarms.
  ...
  SIGNALING LINK STATUS
  SLK PST     LS      CLLI        E5IS
  A   IS-NR  lsgwto2 ----------- INACTIVE

 