Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2212873.1
Update Date:2017-12-28
Keywords:

Solution Type  Problem Resolution Sure

Solution  2212873.1 :   T10000 - Message "Warning: This drive uses SNMPv1" Issued During SSH Communication To Drive.  


Related Items
  • StorageTek T10000D Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-13762118383>

Applies to:

StorageTek T10000D Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Customer has T10KD tape drives and when they use ssh to the drives we see the following error message:

Warning: This drive uses SNMPv1
Using "public" and "private" community strings poses a major security risk.

Changes

 none

Cause

 T10000 has SNMP enabled and only nsmp v1.0 is supported

Solution

No workaround.

Please refer to For SNMP documentation, please refer to StorageTek T10000D Security Guide, http://docs.oracle.com/cd/E48725_03/TTKSC/E28826-02.pdf
look at page 9 of18 or page id 2-1.