Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2212583.1
Update Date:2016-12-12
Keywords:

Solution Type  Problem Resolution Sure

Solution  2212583.1 :   IMT BUS B : Minor IMT Failure Detected  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-13634798561>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Information in this document applies to any platform.

Symptoms

There is one minor IMT bus failure alarm on the bus B

Cause

The issue comes from the shelf 42xx
Indeed, the output of the command rept-imt-info:reprt=hiprerr:sshelf=4200:eshelf=4200:... indicates violation errors
The other shelves are fine.

There are regular violation errors on this card :

Bucket Loc  Low Speed Statistic         BUS A Value BUS B Value
------ ---- -------------------         ----------- -----------
00     4207 IMT Rx Packet CRC Error     0           0
            IMT Rx Packet Format Error  0           0
            IMT Rx Violation Error      25          60
            IMT Rx Command Error        0           0
            IMT Rx FIFO Full            0           0

Also there are regular troubles for this card :

eaglestp 16-11-23 10:51:40 GMT EAGLE5 46.0.3-65.26.29
Card 4207 Module bus_mgr_imtp Line 692 Class 0001 Severity 1
13 b8 96 00 83 96 81 00 06 01 00 00 00 02 ..............
Report Date:16-11-23 Time:10:49:04


 

Solution

The card 4207 has been replaced and it solved the issue
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.