Asset ID: |
1-72-2211627.1 |
Update Date: | 2016-12-08 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2211627.1
:
Congestion On Links Of One International Linkset
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-13779403531>
Applies to:
Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Information in this document applies to any platform.
Symptoms
Some links are having congestion; it is impacting the SMS and LU messages
Cause
Links have regular Error rate issues on the received E1 signal (E1port n°3), and Timer T7 is expiring (delay in acknowledging)
> rept-stat-slk:l2stats=both:loc=4113:port=b30
Service Event Timestamp
TXC/T7 Expired 16-12-06 00:29:27.210
SIOS Received 16-12-06 02:47:58.465
SIOS Received 16-12-06 02:48:55.470
SIOS Received 16-12-06 05:35:37.220
TXC/T7 Expired 16-12-06 06:04:13.440
TXC/T7 Expired 16-12-06 13:10:21.115
TXC/T7 Expired 16-12-06 15:34:49.110
Event Type Event Timestamp
State AERM/Abort Proving 16-12-06 13:05:35.400
State AERM/Abort Proving 16-12-06 13:10:28.145
State AERM/Abort Proving 16-12-06 13:10:33.830
State AERM/Abort Proving 16-12-06 15:34:58.440
> rept-stat-slk:l2stats=both:loc=4113:port=a31
Service Event Timestamp
SUERM Link Failure 16-12-05 22:03:26.175
SIOS Received 16-12-06 01:12:29.360
TXC/T7 Expired 16-12-06 04:03:21.010
SIOS Received 16-12-06 06:45:09.365
SUERM Link Failure 16-12-06 09:08:33.920
SUERM Link Failure 16-12-06 10:10:42.505
SIOS Received 16-12-06 14:18:42.155
SIOS Received 16-12-06 15:28:52.690
SIOS Received 16-12-06 15:29:25.685
Event Type Event Timestamp
Receive SIOS 16-12-06 14:18:42.155
Receive SIOS 16-12-06 15:28:52.690
State AERM/Abort Proving 16-12-06 15:28:55.250
State AERM/Abort Proving 16-12-06 15:30:02.955
State AERM/Abort Proving 16-12-06 15:30:07.895
L2T PCR PCR E1 E1
LOC LINK SLC TYPE SET BPS ECM N1 N2 LOC PORT TS
2103 A17 0 LIME1 11 64000 BASIC ---- ------ 2103 7 1
4305 A9 1 LIME1 11 64000 BASIC ---- ------ 4305 2 1
4113 B30 2 LIME1 11 64000 BASIC ---- ------ 4113 3 13
4305 B9 3 LIME1 11 64000 BASIC ---- ------ 4305 2 2
4113 A31 4 LIME1 11 64000 BASIC ---- ------ 4113 3 14
4305 A10 5 LIME1 11 64000 BASIC ---- ------ 4305 2 3
2103 A18 6 LIME1 11 64000 BASIC ---- ------ 2103 7 3
4305 B10 7 LIME1 11 64000 BASIC ---- ------ 4305 2 4
The errors lead the link to go down and the T7 expiration is an additional factor for congestion on Eagle side.
Solution
To troubleshoot the delivered E1 signal to the links of the linkset, and check the transmission path to identify the responsible part
Attachments
This solution has no attachment