Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2211627.1
Update Date:2016-12-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  2211627.1 :   Congestion On Links Of One International Linkset  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-13779403531>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Information in this document applies to any platform.

Symptoms

Some links are having congestion; it is impacting the SMS and LU messages

Cause

Links have regular Error rate issues on the received E1 signal (E1port n°3), and Timer T7 is expiring (delay in acknowledging)


> rept-stat-slk:l2stats=both:loc=4113:port=b30

  Service Event Timestamp
  TXC/T7 Expired 16-12-06 00:29:27.210
  SIOS Received 16-12-06 02:47:58.465
  SIOS Received 16-12-06 02:48:55.470
  SIOS Received 16-12-06 05:35:37.220
  TXC/T7 Expired 16-12-06 06:04:13.440
  TXC/T7 Expired 16-12-06 13:10:21.115
  TXC/T7 Expired 16-12-06 15:34:49.110

  Event Type Event Timestamp
  State AERM/Abort Proving 16-12-06 13:05:35.400
  State AERM/Abort Proving 16-12-06 13:10:28.145
  State AERM/Abort Proving 16-12-06 13:10:33.830
  State AERM/Abort Proving 16-12-06 15:34:58.440

> rept-stat-slk:l2stats=both:loc=4113:port=a31

  Service Event Timestamp
  SUERM Link Failure 16-12-05 22:03:26.175
  SIOS Received 16-12-06 01:12:29.360
  TXC/T7 Expired 16-12-06 04:03:21.010
  SIOS Received 16-12-06 06:45:09.365
  SUERM Link Failure 16-12-06 09:08:33.920
  SUERM Link Failure 16-12-06 10:10:42.505
  SIOS Received 16-12-06 14:18:42.155
  SIOS Received 16-12-06 15:28:52.690
  SIOS Received 16-12-06 15:29:25.685

 Event Type Event Timestamp
  Receive SIOS 16-12-06 14:18:42.155
  Receive SIOS 16-12-06 15:28:52.690
  State AERM/Abort Proving 16-12-06 15:28:55.250
  State AERM/Abort Proving 16-12-06 15:30:02.955
  State AERM/Abort Proving 16-12-06 15:30:07.895


  L2T PCR PCR E1 E1
  LOC LINK SLC TYPE SET BPS ECM N1 N2 LOC PORT TS
  2103 A17 0 LIME1 11 64000 BASIC ---- ------ 2103 7 1
  4305 A9 1 LIME1 11 64000 BASIC ---- ------ 4305 2 1
  4113 B30 2 LIME1 11 64000 BASIC ---- ------ 4113 3 13
  4305 B9 3 LIME1 11 64000 BASIC ---- ------ 4305 2 2
  4113 A31 4 LIME1 11 64000 BASIC ---- ------ 4113 3 14
  4305 A10 5 LIME1 11 64000 BASIC ---- ------ 4305 2 3
  2103 A18 6 LIME1 11 64000 BASIC ---- ------ 2103 7 3
  4305 B10 7 LIME1 11 64000 BASIC ---- ------ 4305 2 4


The errors lead the link to go down and the T7 expiration is an additional factor for congestion on Eagle side.

Solution

To troubleshoot the delivered E1 signal to the links of the linkset, and check the transmission path to identify the responsible part