Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2211396.1
Update Date:2017-12-28
Keywords:

Solution Type  Problem Resolution Sure

Solution  2211396.1 :   T10000 - 5543 Error  


Related Items
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

Sun StorageTek T10000 Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 5543 error

Cause

FSC Dictionary Description:
MODEL = T10000D
FSC = 5543
(FSC Match Found in Rev. 4.11)

FSC: 5543 AUDIT_FSC_ECP_REEL_AMP_FAULT

MIM Code: NONE

FRU: HARDWARE CONF: 100%

Summary: |POWER AMP |INTERCONNECT |REEL MOTOR |

Field Text:
Reel motor amplifier fault detected by the power amplifier.

Solution

 5543 is a servo amp problem that is detected within the logic of the tape drive. The drive needs to be replaced when these are posted.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback