![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2210868.1 : T10000A/B/C/D - FSC 1700 Errors
In this Document
Applies to:Sun StorageTek T10000 Tape Drive - Version All Versions and laterInformation in this document applies to any platform. SymptomsFSC 1700 is informational only. CauseFSC Dictionary Description: FSC: 1700 ASC_FSC_INV_SAV_CH_STA_ST_ACPT MIM Code: INOPERABLE FRU: MICROCODE CONF: 100% Summary: |INVALID UCODE |DATA RECEIVED | *** | Field Text: Engineering Text: T10000A/B/C/D - This error can occur if one path is issuing motion commands to a drive and another path comes in and issues motion commands to the drive. SolutionThis error can occur if one path is issuing motion commands to a drive and another path comes in and issues motion commands to the drive. This seems to occur more on RTDs. Solution: verify that you are not trying to use the drive as an RTD and a native attached drive on a mainframe host at the same time. Attachments This solution has no attachment |
||||||||||||||||
|