![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2210643.1 : T10000A - Stuck Cartridge and after manual dismount show FSC 5131 in the Display.
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek T10000A Tape Drive - Version All Versions and laterSun StorageTek T10000 Tape Drive - Version All Versions and later Information in this document applies to any platform. SymptomsThe RTD (T10000) in maintenance and with cartridge stuck. Error 1.2.-2.1.4 3955 "Error from device Code: 601 - Drive is loaded", Data=|CDATA|drive 1,2,-2,1,4: rewindUnload FAILED with unitCheck 495E - drive is loaded (cartLabel = SM0008T1, driveType = T10000a, driveFirmware = 1.52.106-5.30)|| After manual dismount: Error 1.2.-2.1.4 1320 "Drive communication time-out 1,2,-2,1,4" Error 1.2.-2.1.4 3955 "Error from device Code: 604 - Drive is not functional", Data=|CDATA|drive 1,2,-2,1,4: getState FAILED, resultCode = 6406|| In Drive Display is showing FSC 5132 CauseMachine Reel Motor problem. FSC: 5132 LOD_FSC_MID_LOAD_UNSLACK_TIMEOUT MIM Code: NONE Field Text:
SolutionReplaced the tape drive T10000A. Attachments This solution has no attachment |
||||||||||||||||
|