Asset ID: |
1-72-2209831.1 |
Update Date: | 2017-12-28 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2209831.1
:
SL8500/ASR - FSC 1321, Failure From Power Supply
Related Items |
- Sun StorageTek SL8500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Remote
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-13750188100>
Applies to:
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
The events occurred in different time.
<event-time timezone="US/Mountain">2016-11-30T09:26:52</event-time>
*** Alarm Description ***
FSC(1321): Failure from power supply - Address: 1,0,0,1,27 - Status: (PowerFail: true)(pr
Suspected Device Address :1.0.0.1.27
"Failure from power supply - Address: 1,0,0,1,27 - Status: (PowerFail: true)(present: true)(24v_ok: false)(pha_bo: false)(phb_bo: false)(phc_bo: false)(pha_pres: false)(phb_pres: false)(phc_pres: false)"
Device Dmod: 516000201033
Tray SN: 516000201033
Device Model: SL8500
<event-time timezone="US/Mountain">2016-11-30T09:58:17</event-time>
*** Alarm Description ***
FSC(1321): Failure from power supply - Address: 1,0,0,1,28 - Status: (PowerFail: true)(pr
Suspected Device Address :1.0.0.1.28
"Failure from power supply - Address: 1,0,0,1,28 - Status: (PowerFail: true)(present: true)(24v_ok: false)(pha_bo: false)(phb_bo: false)(phc_bo: false)(pha_pres: false)(phb_pres: false)(phc_pres: false)"
Device Dmod: 516000201033
Tray SN: 516000201033
Device Model: SL8500
Cause
Customer Electric Maintenance.
Solution
Power_Supply_ECM_PS1_AC1(1.0.0.1.27)
Power_Supply_ECM_PS2_AC2(1.0.0.1.28)
SL8500 - 1321 : "Failure From Power Supply - Address: x,x,x,x,x (Doc ID 1556415.1)
References
<NOTE:2180290.1> - SL8500 - Power Supply Locations for DEM and CIM
Attachments