Asset ID: |
1-72-2209085.1 |
Update Date: | 2018-01-05 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2209085.1
:
T10000B - Tape Drive Is Not Initializing - status "Power up FAILED
Related Items |
- Sun StorageTek T10000B Tape Drive
- Sun StorageTek T10000 Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Need field on-site
Created from <SR 3-13691107811>
Applies to:
Sun StorageTek T10000B Tape Drive - Version Not Applicable and later
Sun StorageTek T10000 Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Symptoms
The tape drive T10000B is not initializing with status not Powered.
In log snapshot show us:
1,2,2,1,2 41 572004006711 unknown T10000b StorageTek notPowered 1.52.203-5.30 0.0.0.0
In Sl8500 report show us:
2016-11-21T15:57:58.141 error 1.2.2.1.2 3955 "Error from device Code: 604 - Drive is not functional", Data:=>controlPower|CDATA|drive 1,2,2,1,2: Power up FAILED, resultCode = 6450 (state = inoperative)||
2016-11-21T15:57:58.336 error 1.2.2.1.2 1303 "Failure from drive Code: 604 - Drive is not functional", Data:=>controlPower|CDATA|drive 1,2,2,1,2: Power up FAILED, resultCode = 6450 (state = inoperative)||
Cause
Problem in Power Supply, drive tray.
Solution
Replaced the Power Supply AC/DC, Drive tray with action plan below.
PN 314345801 [F] Power Supply, AC/DC, 133W, T10000 A and B, Drive Tray
Remove the Power Supply
Caution – ESD Damage Potential. The power supply card contains ESD-sensitive components. Improper handling can result in permanent component damage. Make sure you follow accepted ESD precautions and procedures.
1. Disconnect the cable from the drive power connector.
Note – The drive power cable is attached to the power supply card.
2. Disconnect cables from the power supply card.
Note – The card has four cable connections for the T10000C and T10000D drives.
3. Remove five Torx T10 screws securing the card to the tray assembly.
4. Lift the power supply card out of the drive tray assembly.
Note – You must guide the drive power cable through the bulkhead opening.
5. Place the removed power supply card into an ESD-protective package or onto an ESD-qualified surface.
Replace the Power Supply
Caution – ESD Damage Potential. The power supply card contains ESD-sensitive components. Improper handling can result in permanent component damage. Make sure you follow accepted ESD precautions and procedures.
1. Install the replacement power supply:
a. Guide the power cord through the bulkhead while lowering the power supply card into the tray.
b. Position the card onto the standoffs to align with the center mounting hole.
c. Insert and thread, but do not fully tighten, the center mounting screw.
d. Insert and thread the remaining mounting screws (one at each corner), and tighten all five screws.
Note – Do not fully tighten any mounting screw until all five are threaded.
2. Connect the cable(s) to the power supply card.
3. Connect the power cable to the drive power connector.
Note – Make sure the connectors are fully seated and latched.
Attachments