Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2208678.1
Update Date:2017-12-28
Keywords:

Solution Type  Problem Resolution Sure

Solution  2208678.1 :   SL3000 - RC= 1116 "Drive is Not Online - CheckState dst"  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-13698935591>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

SLConsole shows the drive flashing in intermittent Yellow and Green.

In the log Snapshot the Eventlog shows several RC=1116 messages :-

2016-11-23T11:50:59.679 error 1.1.4.1.3 1116 "Drive is not online - checkState dst" move root scsi1 30072401

Changes

 

Cause

 The drive tray was insecurely locked in position.

Solution

The field engineer powered off the tape drive and re-positioned the drive tray.
 

 

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback