Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2208157.1
Update Date:2016-12-02
Keywords:

Solution Type  Problem Resolution Sure

Solution  2208157.1 :   [16.1] Fake Alarm On Non Provisionable Epap Nodes  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-13548695871>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EPAP 16.1 and later
Information in this document applies to any platform.

Symptoms

An alarm appears on the EPAP GUI stating that no automatic backup is scheduled on a non-prov EPAP.

Cause

In EPAP 16, automatic RTDB backup is expected to be configured and is checked for every 5 minutes. If one is not configured, the alarm is raised.


Customer Visible
[Open Update screen] [Double Click on Activity Text to enable Save operation] [Audit]
This issue has been identified as a bug in EPAP 16. It is fixed in EPAP 16.1
Bug 19149237 [https://bug.oraclecorp.com/pls/bug/webbug_edit.edit_info_top?rptno=19149237] : EPAP16.0: "Automatic Backup not configured" is not getting clear from Non-prov
 

Solution

Commented out the cron that check for and raises the alarm.

References

<BUG:19149237> - EPAP16.0: "AUTOMATIC BACKUP NOT CONFIGURED" IS NOT GETTING CLEAR FROM NON-PROV