Asset ID: |
1-72-2208157.1 |
Update Date: | 2016-12-02 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2208157.1
:
[16.1] Fake Alarm On Non Provisionable Epap Nodes
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
|
In this Document
Created from <SR 3-13548695871>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EPAP 16.1 and later
Information in this document applies to any platform.
Symptoms
An alarm appears on the EPAP GUI stating that no automatic backup is scheduled on a non-prov EPAP.
Cause
In EPAP 16, automatic RTDB backup is expected to be configured and is checked for every 5 minutes. If one is not configured, the alarm is raised.
Customer Visible
[Open Update screen] [Double Click on Activity Text to enable Save operation] [Audit]
This issue has been identified as a bug in EPAP 16. It is fixed in EPAP 16.1
Bug 19149237 [https://bug.oraclecorp.com/pls/bug/webbug_edit.edit_info_top?rptno=19149237] : EPAP16.0: "Automatic Backup not configured" is not getting clear from Non-prov
Solution
Commented out the cron that check for and raises the alarm.
References
<BUG:19149237> - EPAP16.0: "AUTOMATIC BACKUP NOT CONFIGURED" IS NOT GETTING CLEAR FROM NON-PROV
Attachments
This solution has no attachment