Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2207288.1
Update Date:2016-12-09
Keywords:

Solution Type  Problem Resolution Sure

Solution  2207288.1 :   Issue With The Eagle serial Connections : Module uias_cnl.c Line 243 Class 01d0  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-13496925011>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Information in this document applies to any platform.

Symptoms

There is continuous trouble which indicates a mismatch in the configuration between one port of the Terminal Server and the corresponding serial MMI port on Eagle.

Card 1113 Module uias_cnl.c Line 243 Class 01d0

 

Cause

This is a sync issue with the active MASP.

 

Solution

Switching the MASP activity solved the issue and confirmed by switching the MASP again.  It works fine with both MASPs.
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback