![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 2206321.1 : SuperCluster: Step 1 of OEDA Fails in SSC M7 with "ERROR: Missing quorumdiskmgr in SSC nodes" Deploying 12.1.0.2 GI/DB
Applies to:Oracle SuperCluster M7 Hardware - Version All Versions and laterOracle SuperCluster M6-32 Hardware - Version All Versions and later Oracle SuperCluster T5-8 Full Rack - Version All Versions and later Oracle SuperCluster T5-8 Half Rack - Version All Versions and later SPARC SuperCluster T4-4 - Version All Versions and later Oracle Solaris on SPARC (64-bit) SymptomsOCT 2016 through DEC 2016 versions of OEDA will fail at step one with the following message deploying 12C GI/DB environments "Step 1. Validate Configuration File" of OEDA failing in SSC M7 rig with
"ERROR: Missing quorumdiskmgr in SSC nodes"
ChangesUsing the latest OEDA to deploy against new or Existing Oracle SuperCluster systems. CauseThe Quorum Disk Manager feature is not available until the Exafamily image that will be delivered in JAN 2017 QFSDP. SolutionIn the extracted OEDA software modify the following parameter in the ../properties/es.properties file. ENABLEQUORUMDISK=false
References<BUG:24938443> - STEP 1 OF OEDA FAILING IN SSC M7 WITH "MISSING QUORUMDISKMGR IN SSC NODES"Attachments This solution has no attachment |
||||||||||||
|