![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2206091.1 : T10000 - 4909 Errors
In this Document
Applies to:Sun StorageTek T10000 Tape Drive - Version All Versions and laterSun StorageTek T10000A Tape Drive - Version All Versions and later Sun StorageTek T10000B Tape Drive - Version All Versions and later StorageTek T10000C Tape Drive - Version All Versions and later StorageTek T10000D Tape Drive - Version All Versions and later Information in this document applies to any platform. Symptoms4909 permanent error. CauseRFID defective in the tape media. Solution RFID Usage Process
Customer action Required If the data on the tape is not available by some other means then a new SR needs to be opened requesting that the FE go onsite and follow the necessary steps to copy the data off of this tape. Mention internal SR 1359444.1 in the new SR.