Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2205360.1
Update Date:2017-11-27
Keywords:

Solution Type  Problem Resolution Sure

Solution  2205360.1 :   xMF Upgrade to 10.X Failed Due to appserver Missing in Bulkconfig  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-13659066415>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 10.1.0 and later
Information in this document applies to any platform.

Symptoms

In earlyUpgradeChecks.log, following messages are displayed:

ERROR: File /root/bulkconfig need to be corrected!
ERROR: earlyUpgradeChecks() code failed for Upgrade::EarlyPolicy::XMFEarlyChecks
ERROR: Failed running earlyUpgradeChecks() code
ERROR: Early Upgrade Checks Failed!
Early Upgrade Checks finished at 1479318863

Changes

 

Cause

appserver line is missing.

This was the content of the bullkconfig within the restored file:

host,pmfip,PMF,0A,eth01,X.X.X.X,M.M.M.M,G.G.G.G
ntp,ntpserver1,X.X.X.X
ntp,ntpserver2,X.X.X.X
app,appserver2,X.X.X.X
tz,Europe/Paris

Solution

Re-install TPD and restart the upgrade with a valid bulkconfig file.

Create the file manually instead of restoring the backup.
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.