![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2204470.1 : SL150 - CHECK 9151, ROBOT_Z_LOCATE_SNSR_ALWAYS_OFF_EXP_MODULE_6
In this Document
Created from <SR 3-13600233171> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. SymptomsError 9151 after Reset of SL150 during initialization and unable to generate Service Logs from SL150. 2016-11-07T13:19:49.107,9151,ROBOT_Z_LOCATE_SNSR_ALWAYS_OFF_EXP_MODULE_6,1,Module 1 Chassis,,,,,,,,,Check module 7 (expansion module 6) locate sensor, always blocked. Inspect/replace chassis.
CauseZ sensor is unable to detect the robot in Expansion Module 6, it is always blocked. SolutionReplaced the Expansion Module 6 and after that the library complete the initialization with success. References<NOTE:1599469.1> - SL150 - How to Generate and Retrieve a Service Bundle (Health / Error Log) From the StorageTek SL150 Modular Tape Library Firmware 2.01<NOTE:1472418.1> - SL150 - How To Remove/Replace a Base Module Chassis CRU In the StorageTek SL150 Modular Tape Library [VCAP] Attachments This solution has no attachment |
||||||||||||||||||
|