![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2202161.1 : UIM 1018 - MTP received invalid SIO
In this Document
Created from <SR 3-13570477001> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and laterInformation in this document applies to any platform. SymptomsFor which reason does Eagle discard some MSUs. eaglestp 16-11-02 09:42:00 GMT EAGLE5 46.0.3-65.26.29
CauseSTP01 is an international STP, it is likely receiving MSUs from an international platform with wrong SIO values SolutionSIO=c3 means National spare network and SCCP. The platform 2808 is using an SIO=spare national whereas the PC 2808 and PC 3091 are not spare national but likely national PC. The issue has to be checked on the platform 2808, why do they send this SIO value ? Attachments This solution has no attachment |
||||||||||||||||
|