Solution Type  Problem Resolution Sure

Solution  2202161.1 :   UIM 1018 - MTP received invalid SIO  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-13570477001>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Information in this document applies to any platform.

Symptoms

For which reason does Eagle discard some MSUs.

eaglestp 16-11-02 09:42:00 GMT EAGLE5 46.0.3-65.26.29
5969.1018 CARD 2201,A2 INFO REPT-MTPERR: MTP received - invalid SIO
SIO=c3 OPC= 02808 DPC= 03391
LSN=lsn1
Report Date:16-11-02 Time:09:42:00

 

Cause

STP01 is an international STP, it is likely receiving MSUs from an international platform with wrong SIO values
 
Eagle has no reason to peg the counter without receiving invalid SIO. This is not an Eagle issue
 

Solution

SIO=c3 means National spare network and SCCP.

The platform 2808 is using an SIO=spare national whereas the PC 2808 and PC 3091 are not spare national but likely national PC.

The issue has to be checked on the platform 2808, why do they send this SIO value ?