Solution Type  Problem Resolution Sure

Solution  2197740.1 :   Falco Traffic Missing in the xDR Sessions  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-12994936329>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 10.1.0 and later
Information in this document applies to any platform.

Symptoms

The reconstitution session feed by the traffic from the Falco are stopping many times.

Changes

 

Cause

The Falco has many link in input with a lot of SU errors.

Some faulty SU are forwarded by the PMF to the IXP and make the build process crashing that's why the session stop. 

Solution

Disable the Falco Inputs with SU errors.