![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2197311.1 : Octets Are Retransmitted On One Linkset
In this Document
Created from <SR 3-13475442321> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and laterInformation in this document applies to any platform. SymptomsThere are some retransmissions on the link 5107-A CauseThere is a quality issue on the link Service Event Timestamp
In Service 16-05-19 03:23:01.445 ISERM Link Failure 16-07-07 14:38:25.345 In Service 16-07-07 14:55:56.045 TXC/T7 Expired 16-07-07 15:13:53.610 In Service 16-07-07 15:16:37.345 ISERM Link Failure 16-10-13 09:19:14.615 In Service 16-10-13 09:19:16.770 ISERM Link Failure 16-10-13 09:19:19.455 In Service 16-10-13 09:20:16.755 ISERM Link Failure 16-10-13 23:43:31.790 In Service 16-10-14 00:14:46.230 ISERM Link Failure 16-10-17 01:00:13.825
SolutionTo use a BERT tester and check each part involved on the transmission path between the Eagle and the far end, including the far end In this particular case the issue was due to a cable. Attachments This solution has no attachment |
||||||||||||||||
|