Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2195886.1
Update Date:2018-03-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  2195886.1 :   IBM LTO5 - Drive 1,4,1,11 Bay 50 Failed ITDT Test With E6 Error  


Related Items
  • IBM LTO5 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Symptoms
Changes
Cause
Solution
 Applies to:
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-13514079241>

Applies to:

IBM LTO5 Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 Drive failed ITDT testing with E6 error.

Changes

 

Cause

 Defective drive.

Solution

Replaced tape drive.

How to Remove and Replace a Tape Drive in SL8500:ATR:1353584.1:2 (Doc ID 1353584.1)


Created from <SR 3-13514079241>

Applies to:

IBM LTO5 Tape Drive


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback