2194833.1
:
SL48- Tape Drive Over Temperature - Error 80 F0
Related Items |
- Sun StorageTek SL48 Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
|
In this Document
Created from <SR 3-13377774641>
Applies to:
Sun StorageTek SL48 Tape Library - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Error 80 F0
16.09.25 21:20:20.54 LIB/ERR FF FF 00 20 20 20 20 20 20 20 20 20 20 20 20 20
20 20 20 00 00 00 00 00 00 00 00 > HE: drive over-temperature
16.09.25 13:13:12.32 LIB/ERR FF FF 00 20 20 20 20 20 20 20 20 20 20 20 20 20
20 20 20 00 00 00 00 00 00 00 00 > HE: drive over-temperature
16.09.23 21:01:13.51 LIB/ERR FF FF 00 20 20 20 20 20 20 20 20 20 20 20 20 20
20 20 20 00 00 00 00 00 00 00 00 > HE: drive over-temperature
16.09.23 12:28:19.21 LIB/ERR FF FF 00 20 20 20 20 20 20 20 20 20 20 20 20 20
20 20 20 00 00 00 00 00 00 00 00 > HE: drive over-temperature
16.09.22 12:28:58.53 LIB/ERR 04 02 02 4B 47 31 30 30 32 4C 34 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 > HE: drive load timeout
16.09.22 12:28:24.87 LIB/ERR FF FF 00 20 20 20 20 20 20 20 20 20 20 20 20 20
20 20 20 00 00 00 00 00 00 00 00 > HE: drive over-temperature
16.09.21 19:41:50.48 LIB/ERR FF FF 00 20 20 20 20 20 20 20 20 20 20 20 20 20
20 20 20 00 00 00 00 00 00 00 00 > HE: drive over-temperature
Cause
Drive over-temperature.
Solution
1) Power-cycle the unit and retry the operation.
2) Update library and drive firmware to the latest revision.
3) Check ambient temperature to ensure that it is within operating specifications.
4) Verify that the ambient temperature is within the 10 C to 35 C Operating Temperature Range limits.
5) Check all fans to determine whether they are working properly.
References
<NOTE:1449303.2> - Information Center: Sun StorageTek SL48 Tape Library