Solution Type  Problem Resolution Sure

Solution  2194633.1 :   T10000D - 4.11.113 Code Changes  


Related Items
  • StorageTek T10000D Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

StorageTek T10000D Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 Code changes in 4.11.113 - 3F21 FSC 3F21 614A FSC614a

Cause

 Code changes in 4.11.113.

Solution

Bug Number
FSC
Synopsis

24477976
NONE
Fix for HPSS application, support for RAO Unexpected file mark detected.

24615109
614A
Fix for the 614A SNO caused by an SSH dropbear memory leak problem. This code bug was primarily affecting SDP-2 customer sites and if the drives had the Ethernet option of SSH enabled (which is factory default setting) and the drive ran out of available memory the 614A SNO would automatically trigger an automated SR case and a new service ticket would be opened in MOS. This fixes the dropbear memory leak root cause.

24691581
NONE
Fix for an intermittent Media Validation bug.

24698473
3F21
Improvements to the original 3F21 criteria for tape path monitoring. 