Asset ID: |
1-72-2194631.1 |
Update Date: | 2017-11-14 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2194631.1
:
T10000C - 3.62.112 Microcode Changes
Related Items |
- StorageTek T10000C Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
In this Document
Applies to:
StorageTek T10000C Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Code Changes in 3.62.112.FSCs: 3F21 FSC3F21 614A FSC614A
Cause
Code changes in 3.62.112.
Solution
Bug Number
FSC
Synopsis
24690057 21653404
614A
Fix for the 614A SNO caused by an SSH dropbear memory leak problem. This code bug was primarily affecting SDP-2 customer sites and if the drives had the Ethernet option of SSH enabled (which is factory default setting) and the drive ran out of available memory the 614A SNO would automatically trigger an automated SR case and a new service ticket would be opened in MOS. This fixes the dropbear memory leak root cause.
24696918
NONE
This change was a customer RFE where false “cartLoadLimit Alerts” would cause the library (SL8500) trace logs to wrap too often deleting pertinent library events which can make troubleshooting the library difficult. Note that further changes for the cartLoadLimit Alerts will be in the next T10000C code release.
24698192
3F21
Improvements to the original 3F21 criteria for tape path monitoring.
Reference <Document 1680168.1> for assistance with downloading and updating this firmware.
Attachments
This solution has no attachment