Solution Type  Problem Resolution Sure

Solution  2194446.1 :   Eagle Does Not Route The traffic To The New DPC S-007  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-13304379651>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Information in this document applies to any platform.

Symptoms

Eagle does not route answers from DCN to the platform 007

Cause

The new destination is a spare national point code.

There is a configuration mistake in the gttsel table, it is missing an entry in the ITU National spare table
 
The configuration toward the national PC 001 works well, whereas toward the national spare PC s-007 does not work.
There is an entry in the gttsel table for ITU national but not for ITU National spare :

> rtrv-gttsel
 
  eaglestp 16-09-09 10:59:19 IST EAGLE5 45.0.1-64.70.35
  GTI               CG            CDPA            CGPA
  NAT  TT NP   NAI  SSN SELID LSN GTTSET          GTTSET
  *4   0  e164 intl --- none  any intgtt1 (cdgta) ----- (--- )

  GTI               CG              CDPA             CGPA
  NATS TT NP   NAI  SSN SELID LSN   GTTSET           GTTSET
  4    0  e164 intl --- none  lsn02 antispam (cdgta) ----- (--- )
 

 

Solution

To add a routing entry for the MSUs with a national spare Network Indicator and then monitor the traffic.

Either with lsn=any or with lsn=<the lsn connected to the DCN platform>