![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2194446.1 : Eagle Does Not Route The traffic To The New DPC S-007
In this Document
Created from <SR 3-13304379651> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and laterInformation in this document applies to any platform. SymptomsEagle does not route answers from DCN to the platform 007 CauseThe new destination is a spare national point code. There is a configuration mistake in the gttsel table, it is missing an entry in the ITU National spare table > rtrv-gttsel
eaglestp 16-09-09 10:59:19 IST EAGLE5 45.0.1-64.70.35 GTI CG CDPA CGPA NAT TT NP NAI SSN SELID LSN GTTSET GTTSET *4 0 e164 intl --- none any intgtt1 (cdgta) ----- (--- ) GTI CG CDPA CGPA NATS TT NP NAI SSN SELID LSN GTTSET GTTSET 4 0 e164 intl --- none lsn02 antispam (cdgta) ----- (--- )