Symptoms
Changes
Cause
Solution


Created from <SR 3-13153209431>

Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.0 and later
Information in this document applies to any platform.

Symptoms

On the installed DSR system(7.0) the AVP is stored as "Destination-Host[0]" whereas on upgraded(5.0 to 7.0) system it is stored as "Destination-Host" in "capm_rule_action_param" table when instance is selected as "ALL" from GUI.

snapshots from Upgraded and installed system

Changes

 

Cause

There were several code changes done to support the multilevel grouped AVP in DSR 5.0, all the new template created even on the upgraded system will have the “[0]” appended for “ALL” instance, only the existing template with “ALL” instance will have “[0]” missing.

Solution

This is as per designed and it doesn't not has any impact on the signaling.