Solution Type Problem Resolution Sure Solution 2193471.1 : T10000D - Tape Drive With Check 5B5A
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:StorageTek T10000D Tape Drive - Version All Versions and laterInformation in this document applies to any platform. SymptomsT10000D with stuck cartridge FSC 5B5A The problem is occurring with several different cartridges. The problem began with cartridge stuck in drive: 2016-10-09T01:34:53.769 error 0.0.0.0.0 6441 "Director - rewindUnloadResponse() drive 1,3,-2,1,3: rewindUnload FAILED with unitCheck 5B5A - drive is loaded (cartLabel = B00136T2, driveType = T10000d, driveFirmware = 4.08.105-5.40) " Stuck cartridge was removed and drive put back online. After two mounts the problem happened again with another cartridge. 2016-10-11T04:26:58.590 error 0.0.0.0.0 6441 "Director - rewindUnloadResponse() drive 1,3,-2,1,3: rewindUnload FAILED with unitCheck 5B5A - drive is loaded (cartLabel = B00095T2, driveType = T10000d, driveFirmware = 4.08.105-5.40) " Changes
CauseBelow is FSC description: FSC: 5B5A ELEV_FSC_BUCKLE_MOTION_TIMEOUT SolutionReplaced the T10000D, according Service Manual. Attachments This solution has no attachment |
||||||||||||||||||
|