Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2193238.1
Update Date:2017-01-26
Keywords:

Solution Type  Problem Resolution Sure

Solution  2193238.1 :   Oracle ZFS Storage Appliance: Losing iSCSI Target CHAP Secret after reboot  


Related Items
  • Sun ZFS Storage 7320
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-13096871501>

Applies to:

Sun ZFS Storage 7320 - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

 Upon a reboot of the ZFS Appliance loses Target CHAP secret

Cause

 Bug 24502647 - iscsi chap target password on zfs storage appliance gets deleted after reboot

 

Solution

Fix available in Appliance Firmware Micro Release 2013.1.6.7

 

Fix also available in (future) Appliance Firmware Release 2013.1.7.0

 

Workaround:

1)  Resetting the CHAP information from the BUI would work. This should not be followed by a networking interface change, which will trigger the bug.

2)  Disabling authentication on the iSCSI client.

 

 

References

<BUG:24502647> - ISCSI CHAP TARGET PASSWORD ON ZFS STORAGE APPLIANCE GETS DELETED AFTER REBOOT