![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2193238.1 : Oracle ZFS Storage Appliance: Losing iSCSI Target CHAP Secret after reboot
In this Document
Created from <SR 3-13096871501> Applies to:Sun ZFS Storage 7320 - Version All Versions and later7000 Appliance OS (Fishworks) SymptomsUpon a reboot of the ZFS Appliance loses Target CHAP secret CauseBug 24502647 - iscsi chap target password on zfs storage appliance gets deleted after reboot
SolutionFix available in Appliance Firmware Micro Release 2013.1.6.7
Fix also available in (future) Appliance Firmware Release 2013.1.7.0
Workaround: 1) Resetting the CHAP information from the BUI would work. This should not be followed by a networking interface change, which will trigger the bug. 2) Disabling authentication on the iSCSI client.