Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2192863.1
Update Date:2016-10-28
Keywords:

Solution Type  Problem Resolution Sure

Solution  2192863.1 :   IXP Servers Are Not Starting Correctly with Error: "Bringing Up Interface Bond0: Determining IP Information For Bond0"  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  


Servers in an IXP subsystem remain stuck, do not start correctly and are not remotely reachable with message "Bringing Up Interface Bond0: Determining IP Information For Bond0"

In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-13437500184>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 9.0.3 and later
Information in this document applies to any platform.

Symptoms

Several servers are not starting correctly and not reachable and they display the message:

"Bringing up interface bond0:
Determining IP information for bond0... ">

without response (not booting beyond).

Even reboot of the servers and the switches does not change anything. Moreover, rebooting a server that does not encounter the issue in the subsystem, will sometimes put it also in the same stuck situation.

Changes

 

Cause

PM&C/PMAC is not managing correctly IP of servers (DHCP issue).

Solution

Restart the PM&C server and double check after restart has been completed whether the various servers are able to reboot correctly and are reachable thru SSH or not.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.