In this Document
Symptoms
Cause
Solution
References


Applies to:

Fujitsu M10-1 - Version All Versions and later
Fujitsu M10-4 - Version All Versions and later
Fujitsu M10-4S - Version All Versions and later
Information in this document applies to any platform.

Symptoms

M10 XCP firmware does not treat a specific PSU failure as a fault.

The system may lose PSU redundancy, if redundancy is lost and if there is another power event on the remaining PSU(s) the host will come down unexpectedly.

Cause

This is a bug in XCP2250, XCP2260, and XCP2271.

Solution

Please upgrade to XCP2280 or above. 

See document 1554086.1 for more information on M10 XCP Firmware.