Solution Type  Problem Resolution Sure

Solution  2191883.1 :   PDUs Not Correlating Because of Different Matching ID  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-13364718881>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 9.0.4 and later
Information in this document applies to any platform.

Symptoms

MAP¨PDU are not correlated and generate multiple xDRs instead of a single one.

xDR Status of those xDR is Timer in one way and "Not matched" in the other way.

Changes

 

Cause

The way management is not configured on the PMF IP dataflow.

The "not matched" xDR use the STP point code as Matching Id instead of the equipment point code. 

Solution

Way management must be configured.

Most of the time the easiest solution is to configure the STP IP addresses.
 

 