![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2191883.1 : PDUs Not Correlating Because of Different Matching ID
In this Document
Created from <SR 3-13364718881> Applies to:Oracle Communications Performance Intelligence Center (PIC) Software - Version 9.0.4 and laterInformation in this document applies to any platform. SymptomsMAP¨PDU are not correlated and generate multiple xDRs instead of a single one. xDR Status of those xDR is Timer in one way and "Not matched" in the other way. Changes
CauseThe way management is not configured on the PMF IP dataflow. The "not matched" xDR use the STP point code as Matching Id instead of the equipment point code. SolutionWay management must be configured. Most of the time the easiest solution is to configure the STP IP addresses.
Attachments This solution has no attachment |
||||||||||||||||||
|