Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2191480.1
Update Date:2018-05-02
Keywords:

Solution Type  Problem Resolution Sure

Solution  2191480.1 :   Oracle ZFS Storage Appliance: ILOM BUI session closes prematurely, hardware components not viewable  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS5-2
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Oracle ZFS Storage ZS5-4
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun ZFS Storage 7120
  •  
  • Oracle ZFS Storage Appliance Racked System ZS4-4
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: ZS
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-13431276961>

Applies to:

Oracle ZFS Storage ZS4-4 - Version All Versions and later
Oracle ZFS Storage ZS3-2 - Version All Versions and later
Oracle ZFS Storage ZS3-4 - Version All Versions and later
Oracle ZFS Storage ZS3-BA - Version All Versions and later
Oracle ZFS Storage Appliance Racked System ZS4-4 - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

After an ILOM firmware upgrade, the ILOM BUI closes the session within one minute of login, despite user activity.

Hardware components are not viewable.

The problem remains despite rebooting the ILOM.

 

Changes

 

Cause

Web browser cache issue due to a cached copy of the pages from the BUI version previous to the update.

 

Solution

Clear the browser cache.

 

References

<NOTE:1357354.1> - Sun Storage 7000 Unified Storage System: How to Update the BIOS for a 7x10 NAS Appliance
<NOTE:1357409.1> - Sun ZFS Storage Appliance: How to update the BIOS for a 7x20 NAS appliance

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.