Solution Type
Problem Resolution Sure
Solution
2191085.1
:
Both EPAP Servers Reporting Active Status
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
|
In this Document
Created from <SR 3-13450247971>
Applies to:
Oracle Communications EAGLE (Software) - Version EPAP 15.0 and later
Information in this document applies to any platform.
Symptoms
Both EPAP A and B show Active Status
Cause
Investigation show maint.err file has not been updated since 8/15/2016.
That indicates that the what ever status the maint on the A had for B was old and maint on A was probably hung. It is HIGHLY unlikely that it would go 50+ days and not update.
Solution
Killed maint process on A and B. Processes restarted. A is active and B is standby.